-40%

Hubbell GFTRST82ALNL 15A Almond Hospital GFCI Nightlight Tamper Resistant Outlet

$ 9.49

Availability: 57 in stock
  • Quantity: 1
  • Outlet Configuration: Duplex
  • Grade: Hospital Grade
  • MPN: GFTRST82ALNL
  • Plate Design: Decorator/Rocker
  • Wires: 3
  • Voltage: 125 V
  • Recommended Environment: Indoor
  • California Prop 65 Warning: These products may contain a chemical known to the State of California to cause cancer, birth defects or other reproductive harm.
  • Brand: Hubbell
  • Poles: 2
  • Number in Pack: 1
  • Number of Poles: 2
  • Port Type: Power
  • Item Length: 1.500
  • Suitable For: Interior
  • Type: GFCI Outlet
  • Ground: GFCI Ground Fault & Grounding Screw
  • Number of Outlets: 2
  • Room: All Rooms
  • Application: Electrical Wiring
  • Amperage: 15A
  • Terminal Type(s): Back and Side Wired
  • Country/Region of Manufacture: Unknown
  • All returns accepted: Returns Accepted
  • Custom Bundle: No
  • Item Height: 3.300
  • Lot Quantity: 1
  • Color: Beige
  • Gender: Female
  • Number of Gangs: 1
  • Outlet Style: Decorator
  • Orientation: Horizontal/Vertical
  • Body Orientation: Horizontal/Vertical
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Item Width: 1.750
  • Termination Type: Terminal Screws
  • Condition: New
  • Maximum Amperage: 15A
  • Item must be returned within: 60 Days
  • Illumination: Illuminated
  • Model: GFTRST82
  • Protection Device: Ground Fault Circuit Interrupter (GFCI)
  • NEMA Number: 5-15R
  • Features: GFCI Safety Circuit
  • Device Type: Self-Testing Tamper Resistant GFCI Outlet
  • Resistance Properties: Tamper
  • Operation Method: Outlet
  • Return shipping will be paid by: Seller
  • Installation Area: Indoor

    Description

    Fruit Ridge Tools, LLC
    Our eBay Store
    Contact Us
    Add to Favorite Sellers
    Hubbell GFTRST82ALNL 15A Almond Hospital GFCI Nightlight Tamper Resistant Outlet
    Product Details
    Quantity in Lot:
    1
    Brand:
    Hubbell
    Part Number:
    GFTRST82ALNL
    Color:
    Almond
    Type:
    Self-Testing Tamper Resistant GFCI Outlet
    Phase (if applicable) :
    Poles:
    2
    Wires:
    3
    NEMA Number:
    5-15R
    Amperage:
    15A
    Voltage:
    125V
    Grade:
    Hospital Grade
    Terminal Type(s):
    Back and Side Wired
    Ground:
    GFCI Ground Fault & Grounding Screw
    Hubbell GFTRST82ALNL almond Autoguard Self-Test tamper resistant GFCI receptacle with Nightlight. It is Hospital Grade, NEMA 5-15R, 2-Pole 3-Wire Grounding, back and side wired, rated 15A-125V at receptacle and 20A-125V feed-through. Hubbell AUTOGUARD GFCI receptacles continually test and monitor for "people protection capability" automatically. This patented safety feature includes disconnecting power to the receptacle if critical components are damaged and GFCI protection is lost. GFCI auto-monitoring is conducted continuously within every 30 seconds. Hospital grade devices are top of the line in their category, designed for high-abuse environments such as those found in healthcare facilities. Each is individually packaged; packaging may differ from photo. Features include:
    Hubbell AUTOGUARD GFCI receptacles continually test and monitor for "people protection capability" automatically
    Clear visual indicators are provided on the device face representing power status, trip condition, ground fault condition and end of life status
    For added safety, power will be denied to the receptacle face if reverse wiring of line and load was to occur
    Light sensor controls the Night Light feature for automatic "ON/OFF" and custom dual lens for optimum light output
    Patented shutter design for tamper-resistant protection
    Shutter mechanism inside the receptacle blocks access to the contacts unless a two-prong plug is inserted, helping ensure hairpins, keys, etc., will be locked out
    TEST and RESET functions work together so that a tripped GFCI cannot be reset if GFCI circuit no longer provides ground fault protection
    RESET button is blocked if GFCI protection has been compromised, eliminating the possibility of end-users incorrectly assuming that a reset GFCI is providing ground fault protection when it actually is not
    Protection Against Line and Load Reversal - No power to the face or downstream receptacles if device is miswired
    With auto-grounding clip, captive mounting screws and single tab "breakoff" ears and full "breakoff" for OEM raised covers
    Thermoplastic Nylon Housing - this high impact and Ultraviolet Resistant construction provides resilience in harsh environments
    Clear Visual Indication of GFR Status - LED Indicating Lights: Green LED (power to the device); Red LED (trip condition/ground fault condition); Flashing Red LED (end of life)
    Internal Back Wiring Clamp and Guide Pocket provides quick and dependable termination
    Matching standard size thermoplastic wallplate included
    This is New Old Stock and is returnable for any reason. (SKU # HUBGFTRST82ALNL-EA; Weight: 0.35 lbs.)